DSpace Repository

Validation of Hysys Software for Design of a Sieve Tray Column

Show simple item record

dc.contributor.author Ibrahim, Sara Widaat Alla Mohemmed
dc.date.accessioned 2018-11-22T09:41:54Z
dc.date.available 2018-11-22T09:41:54Z
dc.date.issued 2016-11-12
dc.identifier.uri http://repo.uofg.edu.sd/handle/123456789/3038
dc.description A Dissertation Submitted to The University of Gezira in partial Fulfillment of the Requirements for the Award of the Degree of Master of Science in Chemical Engineering Department of Chemical Engineering and Chemical Technology,Faculty of Engineering and Technology November, 2016 en_US
dc.description.abstract The separation of liquid mixtures into their various components is one of the major operations in the process industries . Distillation is the most widely used method of achieving separation of different component in side streams.The types of Distillation Process are Batch Processes and Continuous processes.Sieve trays are simply metal plates with holes in them. Vapour passes straight upward through the column through the plates . The arrangement, number and size of the holes are design parameters, which should be specified .The advantages of sieve trays are simpler and cheaper construction has led to their increasing use; The Objectives of this research is to design a sieve trays column and Comparing the results of using manual calculations with computer software Aspen Hysys. The mixture of acetone-water was separated in a sieve tray column.The equilibrium data were obtained and plotted in diagram to obtain the number of theoretical stages. The design parameters. the column efficiency, column height, tray space and column diameter were calculated .Using the same data, Hysys software was used to determine the above design parameters. These design data were compared with that calculated manually and they found to be satisfactory . number of tray 25,25tary diameter 0.8 m ,0.77 m . weir length 0.64m , 0.60m weir hight 0.045m ,0.05m tery space 0.55m ,0.05m in Hysys software and manunl calculation respectively .this study recommneded Control tuning and stability of the system have to be investigated. further work may be carried out for design of a sieve tray column for multicomponents systems .Flooding against column operation conditions needs to be investigated . en_US
dc.description.sponsorship Gurashi Abdalla Gasmeseed (chair person) Abdalla Mohammed Ahmed Sulman (Co- Supervisor) en_US
dc.language.iso en en_US
dc.publisher University of Gezira en_US
dc.subject separation en_US
dc.subject liquid mixtures en_US
dc.subject process industries en_US
dc.subject Hysys software en_US
dc.title Validation of Hysys Software for Design of a Sieve Tray Column en_US
dc.type Thesis en_US